Rees
MPN # 04962-100
REES Rope Operated Switch, Heavy Duty Manual Reset Taut, Positive Break, 2NO-2NC, 6 A at 110 to 120 VAC, 3 A at 220 to 240 VAC, 1.5 A at 440 to 480 VAC, 1.2 A at 550 to 600 VAC, 2.2 A at 115 to 125 VDC, 1.1 A at 230 to 250 VDC Contact, NEMA 12/13/IP65, Conduit/Surface Mount, 0 to 55 deg C, Aluminum, 8.62 in L x 7.05 in W x 2.47 in H
$919.2121
/ EA
REES Rope Operated Switch, Heavy Duty Manual Reset Taut, Positive Break, 2NO-2NC, 6 A at 110 to 120 VAC, 3 A at 220 to 240 VAC, 1.5 A at 440 to 480 VAC, 1.2 A at 550 to 600 VAC, 2.2 A at 115 to 125 VDC, 1.1 A at 230 to 250 VDC Contact, NEMA 12/13/IP65, Conduit/Surface Mount, 0 to 55 deg C, Aluminum, 8.62 in L x 7.05 in W x 2.47 in H
- With positive break and positive transfer features making it particularly competent for use in emergency stop applications as well as for ordinary circuit control
- The housing is made from high quality die cast aluminum and powder coated painted yellow
- Designed to reduce nuisance tripping often associated with taut cable switches
- Typically found on process applications such as conveyors, transfer machines or assembly lines within the automotive, machine tool, foundry and pharmaceutical industries this switch provides a constant access for emergency or normal stopping
- The rugged construction and long term reliability makes this cable pull switch well suited to function within various environments
- Direction of pull is field convertible
- Manual reset
- Gold plated contacts eliminate high resistance tarnishing
- There are three 1/2 in NPT conduit openings
- The maximum cable recommended cable length is 200 ft with a maximum interval support of 10 ft
- The mechanical life of the switch is 250000 operations
- A600/N300 heavy duty rating
- Operating temperatures at 0 deg C are based on the absence of freezing moisture and liquids
- 60, 30, 15, 12 A inrush current
- 52 lb trip force
- 15 lb operating force between 10 ft supports
- -40 to 85 deg C storage temperature
- 6 A/1.2 A at 110 to 120/550 to 600 VAC, 2.2 A/1.1 A at 115 to 125/230 to 250 VDC
Specifications
- ActionPositive Break
- Contact Configuration2NO-2NC
- Contact Rating6 A at 110 to 120 VAC, 3 A at 220 to 240 VAC, 1.5 A at 440 to 480 VAC, 1.2 A at 550 to 600 VAC, 2.2 A at 115 to 125 VDC, 1.1 A at 230 to 250 VDC
- Dimensions8.62 in L x 7.05 in W x 2.47 in H
- Enclosure TypeNEMA 12/13/IP65
- MaterialAluminum
- Mounting TypeConduit/Surface
- Temperature Rating0 to 55 deg C
- TypeHeavy Duty Manual Reset Taut